Search results for "Dose distribution"

showing 10 items of 14 documents

Cumulative doses analysis in young trauma patients: a single-centre experience

2015

Multidetector computed tomography (MDCT) represents the main source of radiation expo- sure in trauma patients. The radiation exposure of young patients is a matter of considerable medical concern due to possible long-term effects. Multiple MDCT stud- ies have been observed in the young trauma population with an increase in radiation exposure. We have identi- fied 249 young adult patients (178 men and 71 women; age range 14-40 years) who had received more than one MDCT study between June 2010 and June 2014. According to the International Commission on Radio- logical Protection publication, we have calculated the cumulative organ dose tissue-weighting factors by using CT-EXPO software ® . We…

AdultMalemedicine.medical_specialtyAdolescentPopulationDose distributionRadiation DosageEffective dose (radiation)030218 nuclear medicine & medical imagingYoung Adult03 medical and health sciences0302 clinical medicineMultidetector Computed TomographyMultidetector computed tomographymedicineHumansRadiology Nuclear Medicine and imagingYoung adulteducationNeuroradiologyEffective doseeducation.field_of_studymedicine.diagnostic_testbusiness.industryAdsorbed dose; Cumulative doses; Effective dose; MDCT; Tissue-weighting factors; Radiology Nuclear Medicine and ImagingMDCTTissue-weighting factorInterventional radiologyGeneral MedicineCumulative doseSingle centreAdsorbed dose030220 oncology & carcinogenesisWounds and InjuriesFemaleRadiologyNuclear medicinebusinessLa radiologia medica
researchProduct

Monte Carlo Application in Brachytherapy Dosimetry

2009

This paper devoted to Monte-Carlo Applications in BT Dosimetry is organized in four parts: 1. Motivation of the use of Monte Carlo in brachytherapy 2. The use of Monte Carlo to obtain dose distribution around brachytherapy sources 3. Experimental dosimetry versus Monte Carlo 4. Others Monte Carlo applications in brachytherapy

Computer Science::RoboticsPhysicsmedicine.medical_treatmentNuclear engineeringPhysics::Medical PhysicsBrachytherapyMonte Carlo methodmedicineDosimetryDose distributionComputer Science::Other
researchProduct

Radiation leakage study for the Valencia applicators

2011

Abstract Introduction and purpose The Valencia applicators which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands) are designed to treat skin lesions. These cup-shaped applicators are an alternative to superficial/orthovoltage x-ray treatment units. They limit the irradiation to the required area using tungsten-alloy shielding, and are equipped with a tungsten-alloy flattering filter allowing the treatment of skin tumors, the oral cavity, vaginal cuff, etc. The tungsten-alloy thickness to shield radiation is not the same in all parts of the applicators. This fact led us to question whether the leakage radiation differs depending on where it is me…

Film DosimetryMaterials sciencebusiness.industrymedicine.medical_treatmentBrachytherapyBrachytherapyBiophysicsGeneral Physics and AstronomyEquipment DesignGeneral MedicineDose distributionRadiation leakageRadiation ProtectionElectromagnetic shieldingmedicineDosimetryRadiology Nuclear Medicine and imagingRadiochromic filmRadiation protectionNuclear medicinebusinessMonte Carlo MethodLeakage (electronics)Biomedical engineering
researchProduct

Helical Tomotherapy® is a safe and feasible technique for total scalp irradiation

2017

Angiosarcoma of the scalp is a rare aggressive tumor that affects elderly patients. Chemoradiation is the treatment of choice for multicentric and extensive disease. The shape of the scalp represents a dosimetric challenge in terms of achieving a homogeneous concave dose distribution with coverage of the entire target volume and an acceptable organs-at-risk sparing. We report a case of an 81-year-old man with a multifocal angiosarcoma of the scalp treated with Helical TomoTherapy® (Accuray Inc., Sunnyvale, CA, USA) intensity modulated radiotherapy. This technique allows precise and daily verifiable coverage of the target keeping the dose to the organs at risk within the constraints.

Histologymedicine.medical_treatmentPlanning target volumeCase ReportDose distributionTomotherapylcsh:RC254-282Tomotherapy030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineTomotherapy IGRT IMRT Scalp irradiation AngiosarcomamedicineAngiosarcomaAngiosarcomaIMRTIGRTImage-guided radiation therapyExtensive Diseaseintegumentary systembusiness.industrylcsh:Neoplasms. Tumors. Oncology. Including cancer and carcinogensmedicine.anatomical_structureOncologyHomogeneous030220 oncology & carcinogenesisScalpScalp irradiationNuclear medicinebusinessRare Tumors
researchProduct

Inferring postimplant dose distribution of salvage permanent prostate implant (PPI) after primary PPI on CT images

2018

International audience; PURPOSE:To evaluate the dose distribution of additional radioactive seeds implanted during salvage permanent prostate implant (sPPI) after a primary permanent prostate implant (pPPI).METHODS AND MATERIALS:Patients with localized prostate cancer were primarily implanted with iodine-125 seeds and had a dosimetric assessment based on day 30 postimplant CT (CT1). After an average of 6 years, these patients underwent sPPI followed by the same CT-based evaluation of dosimetry (CT2). Radioactive seeds on each CT were detected. The detected primary seeds on CT1 and CT2 were registered and then removed from CT2 referred as a modified CT2 (mCT2). Dosimetry evaluations (D90 and…

MaleBrachytherapy[SDV.CAN]Life Sciences [q-bio]/CancerDose distribution[SDV.MHEP.UN]Life Sciences [q-bio]/Human health and pathology/Urology and Nephrology030218 nuclear medicine & medical imagingIodine Radioisotopes03 medical and health sciencesProstate cancer0302 clinical medicineProstateDosimetryIodine seedsmedicineHumansDosimetryRadiology Nuclear Medicine and imagingRadiometrySalvage TherapyPrimary permanentSalvage brachytherapyProstate cancerbusiness.industryProstateProstatic NeoplasmsProstate implantRadiotherapy Dosagemedicine.disease3. Good healthmedicine.anatomical_structureOncology030220 oncology & carcinogenesisTomography X-Ray ComputedbusinessNuclear medicineSalvage brachytherapy[SDV.MHEP]Life Sciences [q-bio]/Human health and pathology
researchProduct

Model-Based Dose Calculation Algorithms for Brachytherapy Dosimetry

2019

The purpose of this study was to review the limitations of dose calculation formalisms for photon-emitting brachytherapy sources based on the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) report and to provide recommendations to transition to model-based dose calculation algorithms. Additionally, an overview of these algorithms and approaches is presented. The influence of tissue and seed/applicator heterogeneities on brachytherapy dose distributions for breast, gynecologic, head and neck, rectum, and prostate cancers as well as eye plaques and electronic brachytherapy treatments were investigated by comparing dose calculations based on the TG-43 formalism …

MaleCancer ResearchDose calculationmedicine.medical_treatmentBrachytherapyBrachytherapyDose distribution030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineNeoplasmsmedicineHumansDosimetryRadiology Nuclear Medicine and imagingRadiometryHead and neckSocieties MedicalPhotonsTask groupbusiness.industryRadiotherapy Planning Computer-AssistedRadiotherapy DosageModels Theoretical3. Good healthFormalism (philosophy of mathematics)Oncology030220 oncology & carcinogenesisPractice Guidelines as TopicFemalebusinessAlgorithmAlgorithmsSeminars in Radiation Oncology
researchProduct

Mapping of failures after radiochemotherapy in patients with non-metastatic esophageal cancer: A posteriori analysis of the dose distribution in the …

2015

Abstract Background and purpose We aimed to evaluate the patterns of loco-regional failure (LRF) after exclusive chemoradiotherapy (eCRT) for esophageal cancer with respect to planned dose and/or the incidental (unplanned) dose outside target volumes. Materials and methods Co-image registration of CT or 18 F-FDG PET-CT at the time of failure (tf) and at the time of CRT (t0) was performed in 34 patients with LRF. Dosimetric parameters with regard to local failure (LF), nodal failure (NF) and involved nodal stations (NS) were derived. Results Twenty-two patients (64.7%) had LF, the majority of which (95.5%) were located at the epicenter of the GTV of the primary tumor. The mean doses recalcul…

MaleEsophageal NeoplasmsDose distributionPlanned DoseFluorodeoxyglucose F18MedicineNon metastaticHumansRadiology Nuclear Medicine and imagingIn patientTreatment FailureAgedAged 80 and overbusiness.industryLocal failureRadiotherapy DosageHematologyChemoradiotherapyEsophageal cancerMiddle Agedmedicine.diseasePrimary tumorOncologyFemaleLymph NodesNeoplasm Recurrence LocalbusinessNuclear medicineTomography X-Ray ComputedChemoradiotherapyRadiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology
researchProduct

Strategies to change body composition in older adults: do type of exercise and dose distribution matter?

2020

Background: This study aims to analyze changes in sedentary elderlies' body composition, comparing the impact of two dose distributions: continuous (60 min/session) vs. accumulated (30 min/session in the morning and 30 min/session in the afternoon), on two types of physical exercise programs (multicomponent-training [MCT] vs. walking interval-training [WIT]). Methods: Forty-six sedentary overweight elderly (71.3±4.3 years) were evaluated by bioimpedance with a pre-post 2x2 factorial design. Participants were distributed in four homogeneous groups, considering gait and health parameters. Results: The overall sample showed significant improvements in fat mass (% and kg) and fat-free mass (kg)…

Malemedicine.medical_specialtyPhysical Therapy Sports Therapy and RehabilitationPhysical exerciseWalkingDose distributionOverweightsedentary behavioraged.medicineHumansOrthopedics and Sports MedicineAgedMorningexercisebusiness.industryagingWeight controlFactorial experimentOverweightGaitExercise Therapypreventive health servicesHomogeneousBody CompositionPhysical therapyFemaleSedentary Behaviormedicine.symptombusinessThe Journal of Sports Medicine and Physical Fitness
researchProduct

SU-E-T-516: Limitations and Clinical Implications of the TG-43 Formalism for High-Dose-Rate Skin Brachytherapy

2013

Purpose: In high‐dose‐rate (HDR) skin brachytherapy, sources are located outside, in contact with, or implanted at some depth below the skin surface. Nowadays, most TPS use the TG‐43 formalism that is based on sources within an infinite water medium, without accounting for the scatter defect due to surrounding air. The purpose of the present study is to evaluate the limitations of the TG‐43 formalism in HDR skin brachytherapy. Methods: This study examined two HDR sources (Ir‐192 and Co‐60) together with a hypothetical Yb‐169 source. Dose distributions were obtained using Monte Carlo methods (i.e., GEANT4). The following configurations were investigated: 1)A typical clinical case consisting …

Materials sciencebusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineDose distributionFormalism (philosophy of mathematics)Skin surfacemedicineDosimetryClinical caseNuclear medicinebusinessDose rateMedical Physics
researchProduct

TH-C-AUD A-08: Evaluation of Electronic Equilibrium Conditions Near Brachytherapy Sources

2008

Purpose: For high‐energy photon‐emitting brachytherapysources such as 60 Co , 137 Cs , 192 Ir , and 169 Yb , the main contribution of the systematic uncertainty in the dose distributions near the sources is understanding of electronic equilibrium and the contribution of β‐rays due to radioactive disintegration. Thus, it is important to study these effects in detail to accurately depict dose distributions near these brachytherapysources. This work studies the relative importance of β‐ray contributions to total dose (β + γ + x‐ray), and feasibility of using the approximation “collision kerma equals dose in electronic equilibrium conditions.” Method and Materials:Characteristics of kerma and d…

PhysicsRadionuclidebusiness.industryInfraredEquilibrium conditionsmedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineDose distributionKermamedicineDosimetryAtomic physicsNuclear medicinebusinessMedical Physics
researchProduct